WebASHRAE/IES 90.1, Energy-Efficient Design of New Buildings Except Low-Rise Residential Buildings, produced jointly by the American Society of Heating, Refrigerating and Air … Webarea adjacent to the window 3. The width of the zone is the width of the window plus half the window head height one ach side of the window 4. Subtract any area on a plan that is …
ASHRAE 90.1-2013 vs. IECC 2015: Key Differences in Lighting …
WebEach secondary sidelighted area is directly adjacent to a primary sidelighted area (see Figure 3.2-4): a. The secondary sidelighted area width is the width of the vertical fenestration plus, on each side, the smaller of 1. one half of the vertical fenestration head height or 2. the distance to any 5 ft or higher opaque vertical obstruction. b. WebThe combined area within the space of any vertical fenestration in roof monitors shall not be less than 20% of the calculated daylight area under roof monitors. d. Primary sidelighted areas shall have a sidelighting effective aperture of not less than 0.15. e. Secondary sidelighted areas shall have a sidelighting effective aperture of not less ... bin seal
Space-by-Space Method Space-by-Space Method (continued)
Webbe independently controlled by zone. Sidelighted zones must be controlled separately from top lighted zones. Daylight Exceptions: Daylight control is not required when the total … Webprimary sidelighted area: the total primary sidelighted area is the combined primary sidelighted area without double count-ing overlapping areas. The floor area for each … WebPrimary sidelighted areas where the top of the existing adjacent structures are twice as high above the windows as their distance away from the windows. Primary sidelighted areas … daddys burger northampton